On this page
War Rooms
A live, plain-language page about an incident for the people who do not read logs, kept up to date by Obi and your team.
During an incident, the people fixing it are not the only ones who need to know what is going on. A war room is one page about an incident for everyone else: the CEO, support, an account manager about to call a customer. It says what is happening and what is affected in plain words, and it stays up to date while your engineers work.
A war room always belongs to an incident. Obi writes its updates from that incident's alerts, its investigation, and the team's comments on it.
Create a war room
There are two ways in:
- From an incident. Open the incident and press Create war room in its header.
- From the War rooms list. Go to Alerting, War rooms and press Create war room. Pick an ongoing incident that does not have a war room yet, or start from a new incident by giving it a title and a priority.
Either way, the war room settings open next. When you press Create war room, you get the page's link and, if you chose one, its password, each with a copy button.
Once a war room exists, the incident gains a War room tab where you run it, and its header's View war room opens the page in a new browser tab, exactly as the people you share it with see it.
What the page shows
Top to bottom:
- The title and timing. When the incident started and how long it has run, and when the next update is due. If an update is late, or updates are paused, the page says so rather than going quiet.
- Executive summary. Whether the incident is Ongoing, Monitoring or Resolved, a sentence or two about where things stand overall, and when that summary was last updated.
- What is affected. One line per business area, such as Payments or Sign-in, each marked Not working, Partly working, Working normally or Unknown. An area Obi inferred rather than measured is marked Estimated; one a person on the team set is marked Confirmed by the team. While every area is still Unknown, the card shrinks to one line, "Impact not confirmed yet".
- Updates. Every published update, newest first, five to a page, each with who wrote it and when.
The page never shows service names, host names, field names, status codes, stack traces or log lines. Obi's updates are checked for these before they are published, and email addresses and card-number or token-shaped text are masked.
Who can see it
Choose under Who can see it in the settings:
| Setting | Who can read the page |
|---|---|
| Link and password | Anyone with the link who types the password. No account needed. |
| Anyone with the link | Anyone with the link. Treat the link like a password. |
| Members only | Signed-in members of the workspace. |
Every war room has one link, whatever you choose. A signed-in member of the workspace opens it straight away in every mode, without the password, and also gets Open the incident and the investigation's evidence queries. Anyone else opening a members-only war room is asked to sign in, and is told nothing about the incident.
The password is not a secret from your team: it is filled in with a generated three-word passphrase when you create the war room, and members can read it again in the settings and on the War room tab. Changing it signs out everyone who unlocked the page with the old one. Members can open war rooms and post to them; choosing either link setting needs an Admin or an Owner, because it shows incident details to people outside the workspace.
Wrong passwords are limited per address and per war room, and every view, unlock, failed password and lockout is recorded.
Your incidents page
One page can list every war room your workspace has open, so customers and colleagues have a single place to check during an outage. Open it from Incidents page on the War rooms list. Only an Admin or an Owner can change it; other members can read the settings.
Turn on Publish a page listing open war rooms and the page's link appears straight away, ready to copy. It starts working once you save. The page lists only war rooms that are open and shared with Anyone with the link. War rooms with a password or for members only are never listed, and a war room leaves the page when it closes. Turning the page off makes its link answer "Page not found".
The page is called after your workspace, such as "Acme incidents", unless you give it a Title.
Its address
The end of the page's address is its Slug. Every workspace gets one made
from its name, such as acme-incidents, so the box starts filled in. Type
your own to change it: lowercase letters, numbers and hyphens, 3 to 63
characters. Slugs are unique across ObiStack, and the drawer tells you
whether the one you typed is free before you save. Leave the box empty to go
back to the default.
The page also has a long random link, and it keeps working whatever slug you choose, so a link you have already shared never breaks.
Your own domain
To serve war room pages from a subdomain your organization owns, such as
incidents.yourcompany.com, turn on Use your own domain and type it. Use
a subdomain, not a bare domain like yourcompany.com, because most DNS
providers cannot point a bare domain with a CNAME record.
Save, then add the two records the drawer shows at your DNS provider:
| Record | Name | What it does |
|---|---|---|
| CNAME | your domain | Sends visitors to your war room pages. |
| TXT | _obistack-war-room.<your domain> | Proves your organization owns the domain. |
Then choose Check DNS records. Changes usually appear within a few minutes and can take up to an hour. Once the domain is verified, your incidents page opens at its root, and links to war rooms shared with anyone who has the link use it. Members-only war rooms keep the ObiStack address, where members sign in. Keep both records in place: if a later check cannot find them, links go back to the ObiStack address. Turn the switch off and save to stop using the domain.
Keeping it up to date
Obi updates
With the Obi AI Assistant add-on on, Obi writes the updates. Under Obi updates in the settings:
- Obi writes updates. Turn this off to post every update yourself. Obi then writes nothing for this war room, not even a closing summary.
- How often. Every 15, 30, 60 or 120 minutes, or Manual only, where Obi writes an update only when someone presses Ask Obi for an update.
- Post early when things change sharply. A new alert firing, the last one clearing, a deploy to a watched service, or a key number doubling or halving brings the next update forward.
- Publish. Automatically, or After review, where each update waits as a draft on the War room tab until someone publishes, edits or discards it.
- Let Obi read team comments. Obi uses comments on the incident to understand what the team is doing. It never quotes them.
- What Obi can read. Starts on your workspace's setting. You can lower it for this war room alone. If an Owner has given you the permission, you can also let Obi read example log lines here for 24 hours, so it can describe what customers see. The page still never shows a log line.
Obi's updates run as the war room's lead and count toward the workspace's monthly Obi limit, not the lead's own. If the lead leaves or loses access to Obi, updates pause and anyone who can run war rooms can Take over as lead.
Your own updates
Press Write your own update on the War room tab. Alongside the update itself you can:
- Rewrite the executive summary. It starts as the one the page shows now, and is published with your update, so the summary's time always matches the latest update.
- Confirm what is affected. Change an area's state or sentence, add an area or remove one. Areas you change or add show as Confirmed by the team. Obi keeps confirmed areas exactly as you left them in its later updates, and says so in its own words if the data seems to disagree.
A person's update publishes straight away, whatever the Publish setting.
You can also share any comment on the incident to the war room with Share to war room, and Edit or Remove a published update from the War room tab. Neither recalls a notification that was already sent.
Pause and close
Options, Pause updates stops Obi's updates without closing the war room; the page tells viewers updates are paused. Close war room ends it: Obi writes a closing summary of what happened, who was affected and what happens next, and the page stays readable for the period you chose under Keep the page readable after closing for (7 days by default, up to 30). A war room closes on its own when its incident resolves, unless you turn off Close when the incident resolves.
Notify people
Each published update, and the closing summary, can go to the people who need it, chosen under Notify in the settings, with the same controls as an alert rule:
- Notification groups, your workspace's own and any your organization shares.
- Other destinations: email to an address, a member, everyone with a role or the whole workspace; Slack; PagerDuty; or a webhook.
Every email has a link to stop that address getting more from this war room. Emails and messages carry the page's link, never its password. PagerDuty keeps one incident per war room and resolves it with the closing summary. "No change" checks never send anything.
Find every war room
Alerting, War rooms lists every war room in the workspace, open ones first, with its status, who can see it, its last update, its views in the last 24 hours and its link. Incidents with a war room also carry a War room open, War room paused or War room closed chip on the triage board and in the incidents table.
On the War room tab, Views shows how many times the page was opened in the last 24 hours and from how many addresses, with an hourly sparkline. Workspace members' own visits are not counted.